Polarization Maintaining Fiber Tap/Isolator/WDM Hybrid Device PM Fiber Isolator
| Features | ![]() |
| High ER & High Isolation Low Insertion Loss High Stability and Reliability |
|
| Application | |
| Fiber Amplifier Fiber Laser Fiber optic Instrument |
Note:
$100 is a deposit, not the final price of the product. If you are interested in the product, please contact us for the price.
Specifications:
| Parameter | 69:1064/980 | |||
| Isolator stage | Single stage | Dual stage | ||
| Signal Wavelength Range(nm) | 1064±5 | |||
| Signal Tap Ratio (%)(Input to Tap) | 1±0.2, 2±0.4, 5±1, 10±2,50 | |||
| Typ.Signal Peak Isolation(Output to Input) (dB) | 40 | 52 | ||
| Signal Isolation at 23 ℃(Output to Input) (dB) | ≥30 | ≥42 | ||
|
Signal Insertion Loss(Input to Output)(dB) |
Tap 1% | ≤2.7 | ≤3.8 | |
| Tap 2% | ≤2.8 | ≤3.9 | ||
| Tap 5% | ≤3.0 | ≤4.1 | ||
| Tap 10% | ≤3.2 | ≤4.3 | ||
| Tap 30% | ≤4.25 | ≤5.35 | ||
| Tap 40% | ≤4.90 | ≤6.00 | ||
| Tap 50% | ≤5.7 | ≤6.8 | ||
| Pump Wavelength Range(nm) | 960~990 | |||
| Pump Insertion Loss(Pump Channel) (dB) | ≤0.6 | |||
|
Extinction Ratio (Input to Output)(dB) |
Type F (Fast axis blocked) | ≥22 | ||
| Type B (Both of axis working) | ≥20 | |||
| Extinction Ratio (Pump Channel or Tap port) (dB) | 18(only for Pump port or Tap port with PM Fiber) | |||
| Return Loss (all Ports)(dB) | ≥50 | |||
| Directivity (Pump to Tap)(dB) | ≥50 | |||
| Fiber Type | Common /Signal Port | PM980 | ||
| Tap Port | HI 1060 or PM980 | |||
| Pump Port | HI1060 or PM 980 | |||
| Optical Power (mW)(CW) | ≤300 | |||
| Operating Temperature(℃) | 0 ~ +50 | |||
| Storage Temperature(℃) | -40~ + 85 | |||
| Package Dimension (mm) | φ5.5 × L38(P1) (only for bare fiber or 900um loose tube) | |||
| L90*W20*H9.5(ABS)(P2) (only for 3mm or 2mm cable) | ||||
*Above specifications are for devices without the connectors.
*For devices with connectors, IL will be 0.3dB higher, RL will be 5dB lower, and ER will be 2dB lower.
*The PM fiber and the connector key are aligned to the slow axis. And for F type, fast axis is blocked.
Package Dimensions


Ordering Information
| PTIW | Signal & Pump Wavelength | Isolator stage | Pump Type | Coupling Ratio | Working axis | Fiber Type on Pump | Fiber Type on Tap | Pigtail Type | Pigtail Type Length | Connector |
| 69=1064nm Signal/980nm Pump | S=Single Stage D=Dual Stage |
B=Backward Pump F=Forward Pump |
1=1/99 2=2/98 3=3/97 4=4/96 5=5/95 A=10/90 B=20/80 C=30/70 D=40/60 E=50/50 |
F=Fast Axis Blocked B=Both Axis Working |
2=HI1060 3=PM Fiber |
2=HI1060 3=PM Fiber |
1=250um bare fiber 2=900um loose tube 3=3mm loose tube 4=2mm loose tube |
H=0.5m 8=0.8m 1=1.0m 5=1.5m 2=2.0m 3=3.0m 4=4.0m A=2.5m B=5.0m |
0=None 1=FC/UPC 2=FC/APC 3=LC/UPC 4=LC/APC 5=SC/APC 6=SC/UPC |
1310nm 1480nm 1550nm Polarization Maintaining Isolator PM Fiber Isolator
680nm Polarization Maintaining PM Fiber Isolator with PM630 Fiber
1030nm Polarization Maintaining Fiber Optic Isolator with PM980 Fiber
1064nm Polarization Maintaining Tap Isolator PM Fiber Coupler 